Suntec Test Questions
prepared by John J.
Griffin¹
- For each question, click on the response you feel is correct.
- Correct
answers will become bold text.
- Incorrect answers will appear with a line through the
answer.
- Good luck!
- The dynamic Html effects used on this page work only
with Microsoft Internet Explorer 4.0 or later.
- To get the answers for the entire test,
click
here.
1. Which fuel units can be used for both lift and gravity feed
applications?
A.) model
A-2 fuel unit
|
|
B.)
models B-2 & J units
|
|
C.)
models B & H units
|
|
D.) all of the above
|
2. By manufactures specifications, what is the maximum
inlet or return pressure?
|
A.)
3 psi
|
|
B.)
10 psi
|
|
C.)
150 psi
|
|
D.)
300 psi
|
3. Suntec fuel units are available in speeds of 3450 rpm,
2850 rpm, 1725 rpm, and 1425 rpm?
4. What is the maximum vacuum the Suntec Model A-7000
series fuel unit, on a 1 pipe installation, can be used on?
|
A.)
3" Hg
|
|
B.)
6" Hg
|
|
C.)
12" Hg
|
|
D.)
100" Hg
|
5. What is the maximum vacuum the Suntec Model A-7000
series fuel unit, on a 2 pipe installation can be used on?
|
A.)
3" Hg
|
|
B.)
6" Hg
|
|
C.)
12" Hg
|
|
D.)
100" Hg
|
6. Suntec fuel unit model A-7000 series are used on...
|
A.)
#2 fuel or lighter & kerosene
|
|
B.)
#2 fuel only
|
|
C.)
#2 & #4 fuel
|
|
D.)
all of the above
|
7. Suntec model A-7000 series fuel units can be mounted in
what position?
|
A.)
top up only
|
|
B.)
bleeder port up
|
|
C.)
upside down or top up only
|
|
D.)
any position
|
8. What is the adjustable pressure range of a 1725 rpm model A-7000
series fuel unit?
|
A.)
60 - 150 psi
|
|
B.)
100 - 300 psi
|
|
C.)
100 - 135 psi
|
|
D.)
100 - 200 psi
|
9. What is the adjustable pressure range of a 3450 rpm model A-7000
series fuel unit?
|
A.)
60 - 150 psi
|
|
B.)
100 - 300 psi
|
|
C.)
100 - 135 psi
|
|
D.)
100 - 200 psi
|
10. The fuel unit model is listed in two places.
They are?
|
A.)
on the unit label & the shipping carton
|
|
B.)
on the unit label & top of casting
|
|
C.)
on the shipping carton & the bill of lading
|
|
D.)
on the bill of lading & top of casting
|
11. What is the maximum vacuum the model B-8000 series can
be used on, when set up for 2 pipe installation?
|
A.)
6" Hg
|
|
B.)
17" Hg
|
|
C.)
29" Hg
|
|
D.)
100" Hg
|
12. By manufactures standards, the maximum inlet or return
pressure of the model B-8000 series fuel unit is?
|
A.)
3 psi
|
|
B.)
6 psi
|
|
C.)
10 psi
|
|
D.)
300 psi
|
13. What is the maximum nozzle capacity of the B2VA-8216 fuel unit?
|
A.)
3 GPH
|
|
B.)
5 GPH
|
|
C.)
7 GPH
|
|
D.)
15 GPH
|
14. The model B-8000 series fuel unit can be mounted in
any position?
15. The maximum amount of vacuum the B-8200 series &
the B-8800 series can be used on is?
|
A.)
12" Hg
|
|
B.)
17" Hg
|
|
C.)
29" Hg
|
|
D.)
100" Hg
|
16. The maximum nozzle capacity of the model B-8800 series is?
|
A.)
17 GPH
|
|
B.)
7 GPH
|
|
C.)
23 GPH
|
|
D.)
33 GPH
|
17. What is the pressure range of the B-8800?
|
A.)
60 - 100 psi low fire & 100 - 150 psi high fire
|
|
B.)
100 - 150 psi low fire & 100 - 200 psi high fire
|
|
C.)
100 - 200 psi low fire & 100 - 300 psi high fire
|
|
D.)
100 - 200 psi low fire & 200 - 300 psi high fire
|
18. The models B-8200 & B-8800 series fuel units are
used on?
|
A.)
#2 fuel and lighter & kerosene
|
|
B.)
#2 fuel only
|
|
C.)
#2 & #4 fuel
|
|
D.)
all of the above
|
19. The models B-8200 & B-8800 series fuel units can
be mounted in any position?
20. What is the maximum operating vacuum on the Suntec
model J fuel unit used on a 2 pipe installation?
|
A.)
6" Hg
|
|
B.)
12" Hg
|
|
C.)
17" Hg
|
|
D.)
29" Hg
|
21. What is the maximum operating vacuum of a model H fuel
unit on a 2 pipe installation?
|
A.)
6" Hg
|
|
B.)
12" Hg
|
|
C.)
17" Hg
|
|
D.)
29" Hg
|
22. What is the maximum nozzle capacity for a J3 at 1725 RPM?
|
A.)
7 GPH
|
|
B.)
15 GPH
|
|
C.)
24 GPH
|
|
D.)
60 GPH
|
23. What is the maximum nozzle capacity for the model H3BA-100?
|
A.)
7 GPH
|
|
B.)
24 GPH
|
|
C.)
60 GPH
|
|
D.)
83 GPH
|
24. Model J & H pumps are used on?
|
A.)
#2 fuel and lighter & kerosene
|
|
B.)
#2 fuel only
|
|
C.)
#4 fuel only
|
|
D.)
#4 fuel and lighter
|
25. Suntec models J & H fuel units, which begin with
double letters such as JA, JB, JJ, HA, HB or HH are used on 3450 rpm
applications only.
26. The model C solenoid valve may be ordered as a
"Time Delay" valve.
27. The model R solenoid valve may be ordered as a
"Time Delay" valve.
28. The models C & R solenoid valve are rated to?
|
A.)
7 GPH
|
|
B.)
20 GPH
|
|
C.)
27 GPH
|
|
D.)
100 GPH
|
29. When priming any fuel unit, it is recommended to
"wet" the gears so as to...
|
A.)
start the fire at the nozzle as soon as possible
|
|
B.)
assist the fuel unit in priming when lines are dry
|
|
C.)
quiet the fuel unit during the dry run
|
|
D.)
all of the above
|
30. The use of Teflon Tape or compression fittings are
permitted only...
|
A.)
when nothing else works
|
|
B.)
when it is late at night
|
|
C.)
when it is very difficult to flair line
|
|
D.)
never permitted
|
31. When checking pressure on a standard fuel pump, the
reading should be taken at the gauge port?
32. What is the average cut-off pressure for all model A
& B series fuel units set at 100 psi?
|
A.)
60 psi or lower
|
|
B.)
70 psi or lower
|
|
C.)
80 psi or higher
|
|
D.)
100 psi
|
33. The solenoid valve is wired...
|
A.)
in series with cad cell relay
|
|
B.)
in parallel with the cad cell relay
|
|
C.)
in series with the burner motor
|
|
D.)
in parallel with the burner motor
|
34. The by-pass plug is installed on a 1 pipe
installation, never on a 2 pipe installation.
35. In the oil tank, the return line should terminate
approximately 3" - 4" above the supply line. Why?
|
A.)
if necessary to reverse oil lines, the return line will be in oil
|
|
B.)
to prevent air that is being discharged by the fuel unit from being drawn into the
suction line
|
|
C.)
it makes no difference
|
|
D.)
saves on copper oil line
|
36. On the model H series fuel unit, the piston must be
mounted horizontally.
37. All fuel units in a boost pump application should be
piped as a 2 pipe installation.
38. When selecting a boost pump size, what must be taken
into consideration?
|
A.)
cost
|
|
B.)
calculate total fuel demand, size pump at 50% load
|
|
C.)
calculate total fuel demand, size pump at 100% load
|
|
D.)
calculate total fuel demand, size pump at 120 - 150% load
|
39. The amount of fuel moved by a model A-7000 fuel unit in a 2 pipe
application is at least...
|
A.)
7 GPH
|
|
B.)
16 GPH
|
|
C.)
40 GPH
|
|
D.)
60 GPH
|
40. On either a gravity feed or a 2 pipe application, the
distance from the top of the tank to the center line of the fuel unit, per NFPA
limit, must not exceed...
|
A.)
3'
|
|
B.)
8'
|
|
C.)
27'
|
|
D.)
39'
|
41. On a single stage fuel unit piped single pipe, the vertical distance
from the bottom of the tank to the center line of the pump should not exceed...
|
A.)
3'
|
|
B.)
6'
|
|
C.)
8'
|
|
D.)
15'
|
42. On a routine service call, the use of pressure and vacuum gauges are...
|
A.)
not needed
|
|
B.)
used only if a problem is present
|
|
C.)
used if time permits
|
|
D.)
used always
|
|
43. The major area(s) to test on a fuel unit is (are) ....
A.)
vacuum
|
|
B.)
pressure
|
|
C.)
pump cut-off
|
|
D.)
all of the above
|
44. When testing a fuel unit for vacuum, 10" -
15" Hg must be developed and held for...
|
A.)
15 seconds
|
|
B.)
1 minute
|
|
C.)
5 minutes
|
|
D.)
15 minutes
|
45. When testing a fuel unit cut-off, the gauge should...
|
A.)
drop to 0 psi
|
|
B.)
drop 20% or less from set pressure and hold steady
|
|
C.)
drop 20% of set pressure and continue to fall slightly
|
|
D.)
stop at set pressure and hold
|
46. Clogged filters or strainers may cause premature fuel
unit failure because the pump vacuum may be increased beyond the units
capability.
47. Strainers on fuel unit model A & B or J & H
are always interchangeable.
48. If the fuel unit is thoroughly checked during routine
maintenance, a costly service call at 2 am may be avoided.
¹ John Griffin is a service
manager for General Utilities Inc. of Plainview N.Y.
| |